# [Use Case] Trusting AI-agent commands in IEC 61499 operational technology control of geographically dispersed critical infrastructures

## 1. Identification

**Title:** Trusting AI-agent commands in IEC 61499 operational technology control of geographically dispersed critical infrastructures

**Submitting organization:**

**Contact name:** Paolo Campegiani

**Contact email:** [paolo.campegiani@gmail.com](mailto:paolo.campegiani@gmail.com)

**Sector** *(tick all that apply; a cross-industry case may tick more than one)*:

- Critical infrastructure
- Other (specify): Water supply and wastewater utilities. The same architecture applies to other geographically dispersed OT networks (e.g. district heating, gas distribution), and the trust problem it raises applies to any industrial automation domain adopting IEC 61499 (e.g. manufacturing, pharmaceuticals, oil and gas, transport, food and beverage); see "Context" in Section 2

## 2. The situation

>
> Describe the functional interaction: who is acting, what they are trying to achieve,
> and what happens. The trust and security aspects are drawn out in Sections 3 to 5.
>

**Plain language description**: A geographically dispersed critical infrastructure (e.g. a water supply network) is operated through an IEC 61499 function-block architecture distributed over three levels: field devices controlling small groups of pumps and valves, edge devices coordinating each plant or station, and a supervisory level, on premises or in the cloud, coordinating the whole network. An AI agent, deployed as a function block on the field device of a pumping station evaluates which pumps to start and for how long, to satisfy forecasted demand while minimizing energy consumptionwithin an operating envelope delegated by the station's edge-level agent and using the level of the downstream reservoir received directly from the reservoir's field device. Because the link to the supervisory level runs over heterogeneous, low-bandwidth, high-latency and intermittent telecontrol channels, the station must keep operating autonomously, if necessary at the expense of efficiency: the agent's commands are checked and executed locally before the supervisory level can be notified, and are reported to it when the link is restored.

\*\*Context: \*\**From IEC 61131-3 to IEC 61499.* Under IEC 61131-3, trust in field-level logic is implicit: the program is written for a specific controller, compiled for its hardware, validated through factory and site acceptance tests and warranted by the integrator who wrote it, so that its correct execution is bound to that integrator. IEC 61499 deliberately breaks this binding: function blocks are hardware-independent, may be sourced from third-party libraries or marketplaces, and the same function block may be mapped unchanged to field, edge or cloud devices; level-specific function blocks, with different functional specifications, may also be used. The implicit trust anchor disappears and must be replaced by an explicit, verifiable one. AI-agent function blocks make this more acute, because their behaviour cannot be exhaustively verified at commissioning. *IEC 61499 as a substrate for trust.* IEC 61499 is not only the origin of the problem but also a promising basis for its solution, because it defines how function blocks cooperate horizontally (between devices at the same level) and vertically (between field, edge and cloud). Its typed interfaces confine by construction the action space of an agent, which can act only through its declared outputs and the connections defined in the application; adapters are a natural carrier for mandates and operating envelopes as typed contracts; the separation between application and mapping distinguishes the identity of a function block type, of its instance and of its deployment; and the device management model, including online reconfiguration, is the natural point at which deployment and re-attestation can be bound. IEC 61499 is already deployed in production through commercial and open-source implementations, several of which explicitly target IT/OT convergence (see Section 8).

*Decision levels.* In the reference architecture, agentic and non-agentic function blocks operate at three levels, with different scopes and time horizons:


| Level                              | Typical scope of decision                                                                                                                            | Time horizon       | Example of agentic function                                         |
|------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------|---------------------------------------------------------------------|
| Field                              | Small groups of pumps, valves, blowers or centrifuges                                                                                                | Seconds to minutes | Pump scheduling within a delegated envelope                         |
| Edge                               | Efficient and safe operation of a plant or station (e.g. treatment plant, wastewater plant, well field, pumping station; a factory in other sectors) | Minutes to hours   | Plant optimization; derivation of field-level envelopes             |
| Supervisory (cloud or on premises) | Wide-area coordination of plants at provincial, regional or supra-regional scale                                                                     | Hours to days      | Demand forecasting; network-wide scheduling and energy optimization |


*Why the water supply case.* The case was selected because it combines three demanding features: (1) it is a critical infrastructure, subject to the most stringent cybersecurity and resilience obligations; (2) it is distributed over a wide area, often at provincial, regional or supra-regional scale; (3) its telecontrol network relies on heterogeneous physical links (licensed radio, cellular networks, satellite, fibre, leased lines), with bandwidth that may be as low as a few kbit/s, latencies of seconds and outages lasting from minutes to days, so that each site must be able to operate autonomously to ensure service continuity, if necessary at the expense of efficiency. Moreover, there is no universally safe state: stopping pumps may interrupt supply, depressurize the network with risk of contaminant intrusion, or cause water hammer, so the system must be fail-operational rather than fail-safe.

*Cross-sector relevance.* The requirements derived from this case are intended as a superset applicable to other domains adopting IEC 61499, with different emphases: tighter real-time constraints and better local connectivity in manufacturing, where the Machinery Regulation addresses safety components with self-evolving behaviour; validation of computerized systems in pharmaceuticals (GAMP 5, EU GMP Annex 11, draft EU GMP Annex 22 on artificial intelligence); functional safety in oil and gas (IEC 61511); and similar concerns in transport and food and beverage.

**Actor** *(every party involved)*:

**Critical infrastructure owner.** The organization that operates the infrastructure, is responsible for its continuing operation and liable for resulting losses or damage to businesses, assets or people.

**Function block publisher.** The party that develops and publishes function block types, agentic or not, in libraries or marketplaces, possibly for specific levels. It declares the intended purpose of each type and the levels (field, edge, supervisory) at which it may be deployed.

**Model provider.** The party that supplies the AI model embedded in an agentic function block. It may differ from the publisher, and the model may be open source.

**Marketplace operator.** The party that distributes function block types from several publishers.

**System integrator.** The party that composes the application from function block types, defines their mapping to devices and levels, commissions the system and maintains it, including updates to the configuration of agentic function blocks.

**Runtime and device vendors.** The parties that supply the IEC 61499 runtime and the hardware on which it runs; they may be the same party or different ones.

**External data providers.** IT or cloud services that supply inputs consumed by agents, such as demand forecasts, weather data and energy tariffs.

**Human operators.** The staff who work in the control room or in the field, tasked with monitoring the infrastructure, setting operating objectives and intervening manually when needed. At a disconnected station, field technicians may take local manual control through the station HMI, which overrides any agent mandate.

**Sensor.** A physical input interface mapped to an input function block that converts physical process variables into event and data signals for the function-block network. Examples: flow, pressure and level sensors.

**Actuator.** A physical output interface mapped to an output function block that converts event and data signals from the function-block network into physical process actions. Examples: pump motor starters, variable-frequency drives, valve actuators.

**Field device (terminal).** An IEC 61499 device (embedded controller, industrial PC, or controller hardware running an IEC 61499 runtime, typically replacing an IEC 61131-3 PLC) that hosts one or more function blocks and is directly connected to sensors and actuators. In this scenario, it hosts an AI-agent based function block, a guard function block and the output function block that controls some actuators (e.g. a pump).

**Pump output function block.** The function block on the field device that receives control commands (start/stop) forwarded by the guard function block and drives the pump's actuator.

**Guard function block.** A deterministic function block, distinct from the AI-agent function block and running in a separate resource or isolation domain of the field device (e.g. a separate partition or container), anchored to the device's hardware root of trust. It receives the agent's commands and forwards them to the pump output function block only if they are acceptable: it is the point where a command is accepted or refused.

**Edge device (station level).** An IEC 61499 device, typically a hardened industrial computer at or near the station, that coordinates the field devices of one plant or station, hosts plant-level function blocks (agentic or not), derives operating envelopes for the field level from the objectives received from the supervisory level, and reports to it. Existing SCADA/HMI applications may coexist with it for visualization.

**Reservoir field device.** The IEC 61499 field device at the downstream reservoir, which publishes the reservoir level directly to the pumping station's field device over a local radio link, independently of the supervisory level.

**Supervisor.** The central supervisory system that coordinates all the edge devices of the whole infrastructure through dashboards, monitoring, triggers and alerts, operated by the human operators in the control room. It runs on premises or in the cloud, alongside IT systems, and hosts network-level function blocks such as demand forecasting and network-wide scheduling agents.

**AI agent.** Software running inside a function block that implements all or part of the control logic, pursuing the goals assigned by its mandate and possibly invoking other function blocks as tools. In this case it runs on the field device; in other deployments it may run at edge or supervisory level. The same agent function block type may be deployed at several levels, or level-specific types may be used. At field level the model is assumed to be frozen in operation (no online learning).

**Action**: The AI-agent function block on the field device determines that pump 2 should run for 40 minutes to meet forecast demand, and it sends the start command to the guard function block while there is no connectivity with the supervisor. The guard function block checks the agent's identity, the validity of its mandate and the operating envelope, including the reservoir level received from the reservoir's field device, and forwards the command to the pump output function block. The pump starts, and the edge device forwards a report of the action to the supervisor when the link is restored.

*Variants exercising the same decision:*

- (a) *Vertical delegation.* The network-level agent at the supervisory level sets objectives for the station's edge-level agent, which narrows them into the envelope of the field-level agent; each level must verify that the mandate received from the level above has only been narrowed.
- *(b) Horizontal cooperation.* The reservoir's field device and the pumping station's field device exchange level and flow data peer-to-peer, without any hierarchical relationship, while the supervisory level is unreachable.
- *(c) Relocation across levels.* When the station is disconnected, a pre-deployed instance of the network-level scheduling agent on the edge device takes over for the disconnected area: same function block type, different device and level, different authorization.
- *(d) Level-specific function blocks.* Field, edge and supervisory agents are different function block types, with different functional specifications and different admissible deployment levels declared by their publishers.
- *(e) Local manual override.* A field technician takes manual control of pump 2 from the station HMI while the agent is active.

**Decision required**: May the guard function block forward to the pump this start command, issued by an AI agent running inside a function block, under authority delegated through the supervisory and edge levels, while the link to the supervisor is down?

**Problem encountered**: Under IEC 61131-3 this decision is never posed explicitly, because field logic is implicitly trusted as the integrator's hardware-bound program (see Context). With IEC 61499 the issuing agent may be a third-party function block, relocatable across devices and levels, so the decision must be made explicitly. The guard function block cannot make this decision today because: 1) there is no way to verify that the agent issuing the command is the same agent that was accepted into operation by the owner (at installation or at the last maintenance), running on the device and at the level for which it was accepted, and that its model, its configuration, or the underlying hardware and software have not been altered; behavioural drift with unchanged code (e.g. due to a change in the distribution of input data) is a distinct issue, which attestation cannot detect and which requires runtime monitoring; 2) the agent has only partial observability of the network-wide state, so a command that could be optimal at local level (e.g. running pump 2 for 40 minutes to fill the reservoir during a low-tariff period) can violate network-wide constraints such as pressure balance or the availability of a source shared with other stations, that are visible only at higher levels, with no way for the guard to detect this; 3) there is no machine-verifiable representation of relevant physical, legal and safety constraints that can be updated from higher levels as the network state changes, for the guard to check the command before it is executed (static interlocks exist, but cannot express network-derived, time-varying constraints); 4) the agent acts on authority that is the result of a chained delegation process (from the owner to the supervisor, from the supervisor to the edge level, from the edge level to the agent), but today's authentication and authorization mechanisms do not provide a way to manage this chain of delegations effectively and in a semantics-preserving way, nor to manage peer-to-peer relationships between devices of different stations or operators; 5) while the station is disconnected, the guard cannot confirm that the mandate under which the agent acts is still valid (not revoked, not expired, not superseded by a supervisor decision it has not yet received), and judging expiry offline requires a trusted time source on a device that may remain isolated for days; 6) the agent's inputs (demand forecasts, weather data and energy tariffs from IT or cloud services, measurements from peer devices) are not authenticated as to their origin and integrity, so an attested agent acting within a valid mandate and envelope can still be steered by manipulated data; 7) refusing a command is not necessarily safe, because in a water supply network there is no universally safe state, and today there is no way to bind a refusal to a predefined, pre-validated fallback behaviour that preserves service continuity.

**Current mitigation**: AI agents are only adopted at the higher levels of the architecture, mirroring their adoption in security-critical contexts like Security Operation Centers (SOCs), where they work in close contact with human counterparts, providing correlation of events and general views of the system under control. Field-level control is implemented through deterministic logic, typically an IEC 61131-3 program bound to the controller hardware and validated through factory and site acceptance tests, so that trust rests implicitly on the integrator. Where AI components are used, software provenance and assurance rest on ordinary software-engineering practice and on confidence built up over time, without formal or continuing conformity processes. Autonomy during disconnection relies on deterministic fallback logic (e.g. level-based pump control with hysteresis), and telecontrol protocols buffer time-stamped events for later transmission. Where command authentication exists (e.g. DNP3 Secure Authentication, IEC 62351), it authenticates channels and users, not autonomous software components acting under a delegated mandate.

**Residual gap**: No interoperable mechanism lets a function block receiving a command verify, at command time and possibly offline, that the issuing Function Block is the attested agent, acting within its delegated mandate and the physical safety context, on authenticated inputs, and with a predefined fallback that preserves service continuity when verification fails.

## 3. Actors and context

**Taxonomy roles involved**

- Principal — possesses the authority being exercised; source of the mandate: Critical infrastructure owner.
- Relying party — must decide whether to accept the agent's authority: the guard function block (primary, in this case); the edge and supervisory levels, where the output of lower-level agents is consumed, and peer devices exchanging data horizontally (variants (a) and (b)).
- Builder: Function block publisher and model provider (function block types); system integrator (composition of the application and mapping to devices).
- Deployer / Owner: Critical infrastructure owner, by using internal resources or external contractors (system integrator).
- Agent instance: The AI-agent function block running on the field device of the pumping station; in the variants, also the edge-level and network-level agents.
- User: Human operators, who set the objectives the agent pursues and act on its reports; field technicians may override the agent locally.
- Infra provider: Telecom operator providing the WAN for communication between the station and the control room; cloud provider where the supervisor is cloud-hosted; IEC 61499 runtime and device vendors; marketplace operator.
- Attestor: No party performs this role today; the use case is that it is unfilled. Candidates include the owner's OT security function, the hardware root of trust of each device, and conformity assessment bodies where required by regulation.
- Other (specify): External data providers; public authority issuing emergency orders.

**Mandates in this case** *(required)*

>
> List each grant of authority. State the legal regime governing each one: the regime
> fixes what could be conferred, at what moment standing may change, and with what
> continuing effect. A single-regime case is entirely valid. Actor above lists every
> party; this table covers only the authority relationships between them.
>


| Grantor                                                                   | Grantee                                                                              | What is conferred                                                                                                                                                                                                                     | Governing regime                                                                                                                                                          |
|---------------------------------------------------------------------------|--------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Public authority                                                          | Critical infrastructure owner                                                        | Concession or licence to operate the critical infrastructure service, with ensuing obligations.                                                                                                                                       | Sector regulation and concession contracts; obligations for critical infrastructures (depending on the jurisdiction, e.g. NIS2 and the CER Directive for Europe).         |
| Public authority                                                          | Critical infrastructure owner                                                        | Emergency orders (e.g. water shortage, civil protection) that may override efficiency objectives.                                                                                                                                     | National emergency and civil protection law.                                                                                                                              |
| Critical infrastructure owner                                             | System integrator                                                                    | Authority to compose the application, map function blocks to devices and levels, commission and maintain it, including updates to the configuration of agentic function blocks, on the owner's infrastructure.                        | Supply and maintenance contract; responsibilities along the AI value chain (e.g. AI Act Art. 25); due diligence on integrated third-party components (e.g. CRA).          |
| Function block publisher and model provider                               | Critical infrastructure owner                                                        | Licence to use function block types and models, with a declared intended purpose and admissible deployment levels.                                                                                                                    | Licence terms; product obligations under applicable law (e.g. AI Act for providers, CRA for manufacturers, Directive (EU) 2024/2853 on liability for defective products). |
| Critical infrastructure owner                                             | Supervisor (control-room function, operated by staff or by a contracted third party) | Mandate to manage the whole infrastructure within business, legal and technical requirements.                                                                                                                                         | Internal organization and/or outsourcing.                                                                                                                                 |
| Critical infrastructure owner                                             | Human operators (including field technicians)                                        | Authority to take local manual control, overriding any agent mandate.                                                                                                                                                                 | Owner's operating and safety procedures; human oversight obligations (e.g. AI Act Art. 14).                                                                               |
| Supervisor                                                                | Edge device (station level                                                           | Operating objectives, set-points and limits for one plant or station, possibly including coordination with neighbouring stations.                                                                                                     | Technical delegation within the owner's operating procedures, and generally narrower than the supervisor's mandate.                                                       |
| Supervisor                                                                | Pre-deployed instance of the network-level agent on the edge device                  | Conditional authority to take over network-level scheduling for the disconnected area while the supervisor is unreachable (variant (c)).                                                                                              | Technical delegation, with activation conditions defined in advance in the owner's operating procedures.                                                                  |
| Edge device (station level)                                               | AI-Agent based function block (field level)                                          | Authority to manage a specific set of sensors or actuators (inside the same station) that are logically or physically connected, to satisfy operational requirements, within an operating envelope and for a bounded validity period. | Technical delegation within the owner's operating procedures, and generally narrower than the edge mandate.                                                               |
| Critical infrastructure owner (or interconnected operators, by agreement) | Peer field devices (pumping station and reservoir)                                   | Authority to exchange data and coordination requests horizontally, without hierarchical authority (variant (b)).                                                                                                                      | Owner's operating procedures; interconnection agreement where devices belong to different operators (e.g. a bulk water supplier and a distributor).                       |


*Main risks*: a disconnected station does not receive updated delegations; if the system is disconnected, the last received envelopes and policies remain in force without a clear definition of fallback operating procedures; the expiry of a mandate cannot be judged without a trusted time source.

**Cross-border?**

- Yes — jurisdictions involved: a critical infrastructure could span different jurisdictions or, at least, it could be affected by events generated in different countries (cascading effects). Also, the cloud provider could operate in another jurisdiction. Function block publishers, model providers and marketplace operators may also be established in other jurisdictions.

**Embodied (physical actuation or sensing)?**

- Yes — physical context: IEC 61499 primarily deals with Operational Technology (e.g. pumps, valves, sensors in the case of a critical infrastructure like a water supply network). Commands, determined by AI agents, produce physical effects on flow and pressure across the network and affect water availability for people and critical services. There is no universally safe state: stopping pumps may interrupt supply, depressurize the network with risk of contaminant intrusion, or cause water hammer.

**Agent action type** *(required; tick all that apply. Where several apply, the most consequential governs the case)*

- Read-only
- Consequential (reversible): a pump command could be reversed or suspended, but damage (e.g. to the water pipes, or to people) cannot be undone. As such the irreversible case is the most relevant.
- Irreversible: governs the case.

**Crosses organisational boundary?** *(required)*

- Yes (specify): The operating regime of a critical infrastructure could impact systems outside of the owner's control (cascading effect). Also, agentic function blocks may be sourced from third-party publishers and marketplaces, embed models from other providers and be composed and deployed by a system integrator; interconnected operators exchange water and data; the supervisor could be partially outsourced, the WAN connectivity is provided by a telecom operator, and the supervisor could be based on cloud providers' managed services.

**Risk level** *(required)*

- High: physical actuation on critical infrastructure, with potential for irreversible harm.

## 4. Theme relevance

>
> Check every theme this situation exercises, mark the single primary theme, and justify
> each checked theme against Section 2 above. If your case maps to specific theme
> proposals in the themes repository, link them below.
>


| Theme                               | Yes | Primary | Justification (required if checked)                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            |
|-------------------------------------|-----|---------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Dynamic Identity                    | [X] | [ ]     | An IEC 61499 function block can be redeployed across field, edge and supervisory devices without code changes, and its model or configuration can change at maintenance. The same function block type may run at several levels with different authorizations, so identity must distinguish the function block type (code and model), the instance (parameters and connections in the application) and the deployment (device and level). The receiving block relies on an identity that must be derived from the agent, its version and its host, and be re-established after each change, checked against a list of authorized identities (Problem 1; variants (c) and (d)). |
| Continuous Trust and Attestation    | [X] | [X]     | The decision outlined in Section 2 depends on the guard being able to verify, at command time, that the issuing function block is the attested agent and has not been altered since deployment (Problems 1 and 5). Every other element of the decision presupposes this, which is why this theme is marked as primary rather than Delegation. Continuous trust also extends to the inputs the agent consumes (Problem 6).                                                                                                                                                                                                                                                      |
| Delegation                          | [X] | [ ]     | There is a hierarchical delegation model that propagates delegation through the different levels of the system, with verification required at every level. At the end of the chain, the guard must be able to verify that the command is within the received mandate, and that the mandate is still valid, taking into account the risks associated with a loss of connectivity (Problems 4 and 5). Delegation runs vertically across field, edge and supervisory levels and horizontally between peer devices without hierarchical authority, and must coexist with local human override (variants (a), (b) and (e)).                                                         |
| Discovery and Cross-Border Trust    | [X] | [ ]     | Function block types are discovered and sourced from libraries and marketplaces of several publishers, possibly in other jurisdictions, and must be accepted by the owner for specific levels before deployment; maintenance may add new components that must be integrated with existing ones. At runtime, devices cooperate with peer devices of other stations or of interconnected operators and must establish trust in the data and requests they exchange. Conformity and compliance could be verified by supra-national organizations and interconnections between critical infrastructures are a common problem.                                                      |
| Runtime Enforcement (Control Plane) | [X] | [ ]     | The guard function block must enforce the physical and safety envelope on each command locally, in an isolation domain separate from the agent, and switch to a predefined continuity-preserving fallback when a command is refused. Also, the supervisor function is the control plane of the entire infrastructure and it needs to be in full control of the system, as it is always accountable for all of the performed actions and consequences (Problems 2, 3, 5 and 7).                                                                                                                                                                                                 |
| Embodied AI Identity and Trust      | [X] | [ ]     | Due to the operating constraints of the system, AI agents are operating locally, and they need to be embodied with identities used in the trust and risk framework that is operating at station level, anchored to the hardware root of trust of each device. Note that different stations, deployed over different times, could be based on different technologies.                                                                                                                                                                                                                                                                                                           |


**Related theme proposals**:

## 5. Requirements

>
> One row per requirement. Add rows as needed. Type: Legal / Business / Technical.
> Technical requirements are the primary output; include legal or business requirements
> where they bear on a technical decision. Criticality: Must / Should / Nice-to-have.
>


| #  | Type (choose one) | Requirement description                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            | Criticality (choose one) |
|----|-------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------|
| 1  | Technical         | **Attestation of the issuing agent.** Before accepting a command, a relying party shall be able to verify the identity of the issuing agent and the integrity of its current state (function block type, embedded model, instance parameters and connections, hosting device and level) against reference values established when the owner accepted that agent into operation at that level. Verification shall be possible locally and offline, and any change to the agent or its host, including redeployment or online reconfiguration, shall require new attestation before its commands are accepted (Problem 1). To fit field-level resources, full verification may be performed at deployment and per session, with a lightweight check on each command. | Must                     |
| 2  | Technical         | **Verifiable delegated authority.** Each command shall be traceable to a mandate derived from the principal through a chain of delegations, in which each step can only narrow the authority received. The relying party shall be able to verify that the command falls within that mandate and that the mandate is still valid, including while disconnected, using a trusted time source with bounded drift; when validity can no longer be established, the fallback defined in requirement 7 shall apply (Problems 4 and 5). Delegation shall support vertical chains across field, edge and supervisory levels and horizontal relationships between peer devices, and shall recognise local manual override as defined in requirement 11.                     | Must                     |
| 3  | Technical         | **Independent operating envelope.** The physical, safety and network-wide constraints that bound an actuator shall be expressed in a verifiable form under the owner's authority, versioned and updatable from higher levels as the network state changes, and enforced independently of the agent, so that a command outside them is refused (Problems 2 and 3).                                                                                                                                                                                                                                                                                                                                                                                                  | Must                     |
| 4  | Legal             | **Accountability.** Every accepted or refused command, and every acceptance of an agent version into operation, shall leave a tamper-evident record identifying the parties and evidence involved, so that responsibility between the owner, the function block publisher, the model provider, the system integrator, the runtime and device vendors and other parties can be allocated under contract and applicable law, including responsibility for the composition of individually conformant function blocks. The record shall include the inputs and, where available, the rationale of each agent decision, stored locally and transferred when bandwidth allows.                                                                                          | Must                     |
| 5  | Business          | **Fitness for OT environments.** The mechanisms shall operate within the event-to-actuation deadlines of the process on resource-constrained field hardware, remain maintainable over the long operating life of OT equipment, allow components to be added or replaced at maintenance without manual reconfiguration of every device, and coexist with existing deterministic control, legacy IEC 61131-3 controllers, telecontrol protocols (e.g. IEC 60870-5-104, DNP3, Modbus) and independent safety systems without requiring their modification.                                                                                                                                                                                                            | Must                     |
| 6  | Technical         | **Isolation of the enforcement point.** The point where commands are accepted or refused shall run in an isolation domain separate from the agent function block (separate resource, partition, container or device), anchored to a hardware root of trust, so that a compromise of the agent does not compromise enforcement (Problems 1 and 3).                                                                                                                                                                                                                                                                                                                                                                                                                  | Must                     |
| 7  | Technical         | **Continuity-preserving fallback.** When a command is refused or a mandate can no longer be validated, the station shall switch to a predefined, deterministic, pre-validated and level-specific fallback behaviour aimed at preserving service continuity, defined through a risk assessment process (e.g. IEC 62443-3-2 combined with process hazard analysis); the operating envelope may narrow progressively with the duration of the disconnection (Problems 5 and 7).                                                                                                                                                                                                                                                                                       | Must                     |
| 8  | Technical         | **Input provenance and integrity.** Inputs consumed by agents, whether from IT or cloud services or from peer devices, shall be verifiable as to origin and integrity and checked for plausibility against local measurements before use (Problem 6).                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                              | Must                     |
| 9  | Technical         | **Constrained telecontrol links.** Attestation evidence, mandates, envelope updates and revocations shall be compact enough for links of a few kbit/s and support store-and-forward; revocations shall be delivered to disconnected sites as soon as any link becomes available (Problem 5).                                                                                                                                                                                                                                                                                                                                                                                                                                                                       | Should                   |
| 10 | Technical         | **Level-aware authorization of function block types.** Function block types shall be signed by their publisher and accompanied by a bill of materials including the embedded model and by a declaration of intended purpose and admissible deployment levels; the owner shall authorize each type for specific levels and devices, so that the same type may be accepted at one level and refused at another (Problem 1).                                                                                                                                                                                                                                                                                                                                          | Should                   |
| 11 | Legal             | **Human override.** Local manual control by authorized operators shall take precedence over any agent mandate, shall be recognised by the enforcement point and shall be recorded (human oversight obligations, e.g. AI Act Art. 14).                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                              | Must                     |
| 12 | Legal             | **Continuity of operation**. A water supply network (and any critical infrastructure at large) must always be in an operation mode, possibly degraded for *force majeur*, but it cannot simplicistically shut down, as this could result in major incidents and risks for people and the environment.                                                                                                                                                                                                                                                                                                                                                                                                                                                              | Must                     |


## 6. Assessment criteria

**Success criteria:** In a test configuration with a field device hosting an AI-agent function block, a guard function block and a pump output function block, disconnected from the supervisor:

1. A command from an agent whose model or configuration differs from the accepted reference values is refused.
2. A command outside the current operating envelope, including constraints derived from the network state and received from the edge level, is refused, even when issued by a correctly attested agent under a valid mandate.
3. A command issued under an expired or revoked mandate, or after the maximum disconnection time, is refused, and the station enters the named fallback mode<, which keeps the reservoir level within its operating band for a specified duration.
4. A valid command from an attested agent under a valid mandate is executed (without any network access).
5. An agent function block redeployed to another device or level is not accepted until its new identity has been attested and authorized for that device and level.
6. On reconnection, the supervisor receives and reconciles the complete record of accepted and refused commands, including the mandate and envelope under which each decision was taken, with no gaps.
7. A command within the envelope but derived from manipulated inputs (e.g. a falsified demand forecast or peer measurement) is not executed, because the manipulated input fails the provenance or plausibility checks.
8. In a vertical chain (supervisory, edge, field), a mandate that widens the authority received from the level above is refused.
9. Data or requests from a peer device not authorized for horizontal cooperation are ignored, while those from the authorized reservoir device are used.
10. A function block type obtained from a marketplace but not authorized by the owner for field level is not executed on the field device.
11. Local manual control by an authorized operator takes precedence over the agent and is recorded.


Today, criterion 2 can be shown only for static limits (deterministic interlocks), criterion 6 only for process data (event buffering of telecontrol protocols) and criterion 5 only partially (authenticated deployment). None of the criteria can be shown for network-derived envelopes, delegated mandates, attested agent identity or input integrity, because the receiving function block has no basis for refusing a command from a co-located function block other than its own hard-coded limits.

**Measurable metric:**

- Verification latency relative to the event-to-actuation deadline of the process (IEC 61499 execution is event-driven).
- False acceptance rate on a frozen set of negative test cases covering criteria 1, 2, 3, 5 and 7 to 10.
- False refusal rate on valid commands during normal operation, both connected and disconnected.
- Fraction of executed commands with a complete attributable record (identity, mandate, envelope version, inputs).
- Time from reconnection to full reconciliation of the station's record at the supervisor.
- Memory and processing overhead of verification on the field controller.
- Bandwidth overhead of the trust mechanisms on the telecontrol link.
- Maximum clock drift tolerated while judging mandate validity offline.
- Service continuity under disconnection (e.g. time for which the reservoir level is kept within its operating band) and efficiency loss (e.g. additional energy consumption) compared with connected operation.

## 7. Duplication check

>
> Required under ITU-T Recommendation A.7 clause 7: the Focus Group does not duplicate work underway in ITU-T study groups or other bodies.
>

**Existing standards or SDOs** *(which existing work touches this case)*:

*Industrial automation and OT security:*

- IEC 61499, Function blocks (architecture, distribution and deployment of function blocks).
- IEC 61131-3, Programmable controllers: programming languages (the current paradigm, in which control logic is bound to controller hardware and to the integrator).
- IEC 62443 series, Security for industrial automation and control systems, in particular 62443-3-2 (security risk assessment), 62443-4-1 (secure product development lifecycle), 62443-2-4 (service providers), 62443-3-3 (system security requirements) and 62443-4-2 (component security requirements).
- IEC 61508 and IEC 61511, Functional safety.
- IEC 62541, OPC Unified Architecture (application and device identity, security model).
- IEC 62351 series, in particular parts 5 and 8 (security of telecontrol protocols, role-based access control), and DNP3 Secure Authentication (IEEE 1815).
- IEC 60870-5-101/104, DNP3 and Modbus: telecontrol protocols with which IEC 61499 communication will coexist.
- IEC 62264 (ISA-95), Enterprise-control system integration (functional levels).
- IEC 63278, Asset Administration Shell (digital representation of assets, a possible carrier of declared identity and capabilities).
- Open Process Automation Standard (O-PAS, The Open Group): portability and interoperability of control software across hardware.
- VDI/VDE/NAMUR 2658, Module Type Package: orchestration of autonomous process modules.

*Attestation, identity and delegation:*

- IETF RFC 9334, Remote ATtestation procedureS (RATS) architecture, and RFC 9711, Entity Attestation Token.
- TCG DICE, Device Identifier Composition Engine.
- IETF RFC 8693, OAuth 2.0 Token Exchange (delegation and actor claims).
- W3C Verifiable Credentials.

*ITU-T SG17:* agentic AI security and identity items already listed in submission #5 (e.g. X.aaia-sec, X.S-AIAI, X.aiidm, X.dpidm-aAI).

*AI management and regulation:*

(The list reflects author's knowledge which is more rooted in European norms, but similar laws are defined in many legal systems)

- ISO/IEC 42001, AI management system.
- Regulation (EU) 2024/1689 (AI Act), Annex III point 2: AI systems used as safety components in the supply of water are high-risk; also relevant: Art. 3(23) (substantial modification), Art. 12 (record-keeping), Art. 14 (human oversight) and Art. 25 (responsibilities along the AI value chain).
- Directive (EU) 2022/2555 (NIS2): drinking water and waste water operators are essential or important entities.
- Directive (EU) 2022/2557 (CER Directive): resilience of critical entities, including drinking water.
- Regulation (EU) 2024/2847 (Cyber Resilience Act): obligations on products with digital elements, including agent software distributed through libraries and marketplaces.
- Directive (EU) 2024/2853 on liability for defective products, which covers software.
- Regulation (EU) 2023/1230 (Machinery Regulation): safety components with self-evolving behaviour (relevant to the manufacturing generalisation).
- EU GMP Annex 11, GAMP 5 and draft EU GMP Annex 22 on artificial intelligence (relevant to the pharmaceutical generalisation).

**Overlap notes** *(why the work named above does not already solve this)*:

IEC 61499 defines how function blocks are composed, distributed and deployed, but not how one function block establishes the identity, integrity or authority of another. Its typed interfaces, adapters, separation between application and mapping, and device management model nonetheless provide natural anchoring points for the mechanisms requested here (see Context). IEC 61131-3 does not need such mechanisms, because trust is implicit in the integrator's hardware-bound program; IEC 61499 removes that implicit anchor. IEC 62443 provides device and component identity, zones and conduits and security levels, but treats software inside a device as part of that device and has no notion of an autonomous component acting under delegated authority, nor of a mandate whose validity must be judged offline, which is exactly the relevant and interesting case for AI agents. IEC 61508/61511 provide independent safety layers, which this use case assumes remain in place (row 5); they bound the worst outcome but do not let the control layer refuse a non-conforming command before it reaches the safety layer, nor do they express network-derived, time-varying constraints. Open Platform Communications Unified Architecture provides application-instance identity and secure channels, which could carry the bindings in rows 1 and 2, but does not define agent attestation or chained mandates.

IEC 62351 and DNP3 Secure Authentication authenticate telecontrol commands and support role-based access control, but they authenticate channels and users, not an autonomous software component acting under a chained mandate verifiable offline, and they do not address software that is portable across devices and levels. O-PAS and MTP address portability and orchestration of control software and process modules, but not the attestation of agentic components or delegated authority. The Asset Administration Shell could carry the declarations required by row 10, but does not define how they are verified.

RATS, EAT and DICE provide the building blocks for row 1 at device level; the gap is their application at function-block granularity, with reference values tied to the owner's acceptance of an agent version, and appraisal by a co-located relying party without a remote verifier. OAuth Token Exchange and Verifiable Credentials can express delegation, but typically assume an online authorization server or status service; neither defines offline validity bounds with a fallback mode (row 2) or binding to a physical operating envelope (row 3), and neither addresses the size constraints of low-bandwidth telecontrol links (row 9).

The ITU-T SG17 agentic AI items address agent security and identity in general, mostly in IT and telecommunication settings; none identified addresses real-time constraints, physical envelopes or disconnected operation in OT. The AI Act, the NIS and the CER Directives, the CRA and the Product Liability Directive impose obligations this use case helps make verifiable (row 4 and row 11) but do not specify technical mechanisms. Note that while these regulations are European in nature, reflecting the author's direct knowledge, other countries and regions in the world have similar regulations.

No identified work specifies how a field-level function block can verify, at command time and offline, that a co-located AI-agent function block is the attested agent acting within a delegated mandate and a physical operating envelope, on authenticated inputs and with a continuity-preserving fallback. The proposer will amend this section if FG-TIDA participants identify overlapping items.

## 8. Maturity

**Pilot status**

- Hypothetical (agentic function blocks and trust layer)
- Pilot in progress
- Deployed in production

The underlying IEC 61499 architecture is not hypothetical: it is deployed in production through several commercial and open-source implementations (e.g. Schneider Electric EcoStruxure Automation Expert, which explicitly targets IT/OT convergence; Eclipse 4diac; the shared runtime managed by UniversalAutomation.org). What is hypothetical is the use of AI-agent function blocks at field level and the trust layer requested in Section 5.

**Reference implementation:** at the time of submission, a prototype could be built on an open-source IEC 61499 runtime (e.g. Eclipse 4diac) to make the negative test cases of Section 6 reproducible, and then validated on commercial runtimes.

## 9. IP and confidentiality

**Confidentiality level**

- Public
- FG-internal only
- Redact before publication

**IP notes** *(optional)*: No IPR is claimed on the content of this submission. The requirements in Section 5 are implementation-neutral and do not depend on any proprietary technology of the submitting organization. Implementations named in Section 8 are cited only as evidence of the maturity of the underlying architecture.

## 10. Assets

**Link to assets:**

- Dataset
- Code
- Protocol
- Other:

No assets are available at the time of submission. Any future prototype, test configuration or negative test cases will be published with explicit licences and linked here.

 ~~ **IP notes** *(optional)*: As above. ~~ 

 