[Use Case] Evidence-gated release and lifecycle control for a hospital-deployed medical AI agent
Contribution number FG-TIDA-WG0-005
Versions:
| Document | Author(s) | Steven Zhao (independent expert) |
|---|---|---|
| Affiliation(s) | Independent expert | |
| Submission contact | zhaoxinghua06@126.com | |
| Version | 0.0 · recorded | |
| Last updated | 2026-11-06 20:06 UTC | |
| Formats | MD Text GitHub reference | |
| FG-TIDA workflow | State | Submitted |
| Working group / stream | WG0: Use Cases, Taxonomy, and Terminology (UCT) | |
| History | Decisions and changes · latest activity 2026-11-13 11:32 UTC | |
| Secretariat | tsbfgtida@itu.int |
GitHub source classification
- fg-tida-wg0/use-cases · issue:53 · GitHub issue: open
Archived versions
| Version | Recorded | GitHub tag | Release artifacts |
|---|---|---|---|
| 0.0 | 2026-11-06 20:06 UTC | — | — |
Complete every field. Replace the angle-bracket placeholders. Tick boxes with [x].
1. Identification
Title: Evidence-gated release and lifecycle control for a hospital-deployed medical AI agent Submitting organization: Independent expert Contact name: Steven Zhao (independent expert) Contact email: zhaoxinghua06@126.com
Sector (tick all that apply; a cross-industry case may tick more than one): - [ ] Education - [ ] Displaced persons / humanitarian - [x] Health - [ ] Financial services - [ ] Telecom - [ ] Media and publishing - [ ] Logistics - [ ] Energy - [ ] Critical infrastructure - [ ] Smart home / IoT - [ ] Other (specify):
2. The situation
Describe the functional interaction: who is acting, what they are trying to achieve, and what happens. The trust and security aspects are drawn out in Sections 3 to 5.
Plain language description (required, 3 sentences max): A hospital deploys an AI agent that drafts diagnostic findings from imaging and clinical data on behalf of the hospital's clinicians. Before any finding is acted on, the hospital must decide whether this specific agent instance is currently trustworthy enough to act — and must keep re-deciding as the model, its evidence base, or the patient population changes. Today that decision is made once, at procurement, and never re-examined at runtime.
Actor (every party involved): - Device manufacturer (model owner, builder) - Hospital / clinical deployer (principal and owner of the deployment) - Agent instance - Reviewing clinician (user and relying party) - National regulator / notified body (attestor)
Action: The agent instance produces a draft finding that enters the clinical decision workflow. Decision required (at the moment the agent acts, what does the party on the receiving end have to decide? Write it as a question): "May this agent instance, on this model version, be allowed to produce findings for our patients right now — and if not, what evidence would change the answer?" Problem encountered (why that decision cannot be made today): The decision requires evidence that lives with the manufacturer (validation studies, change-control status, drift monitoring) while the risk is carried by the hospital; there is no standard, machine-checkable way to express "what evidence is required, at what grade, re-checked when" across this organizational boundary. Current mitigation: One-time procurement review; contractual warranties; periodic manual audits. Residual gap: No runtime gate vocabulary: no agreed scale for evidence strength, no distinction between "evidence absent" and "evidence found wrong", no standard trigger for re-evaluation when the model or its policy reference changes.
3. Actors and context
Taxonomy roles involved - [x] Principal — the hospital, on whose behalf (and patients) the agent acts - [x] Relying party — the reviewing clinician / hospital governance, who must decide whether to accept the agent's output - [x] Builder — device manufacturer - [x] Deployer / Owner — hospital IT / clinical governance - [x] Agent instance - [ ] User — interacts with the agent; may or may not be the principal - [ ] Infra provider - [x] Attestor — regulator, notified body, or independent evaluation party - [ ] Other (specify):
Mandates in this case (required)
List each grant of authority. State the legal regime governing each one.
| Grantor | Grantee | What is conferred | Governing regime |
|---|---|---|---|
| National regulator | Manufacturer | Market authorization for the AI-enabled device within a cleared intended use | National medical-device regulation for AI-enabled software (incl. change-control-plan regimes for locked models) |
| Manufacturer | Hospital | Right to operate the deployed model on local patient data within the cleared intended use | Procurement / deployment agreement + institutional clinical governance |
| Hospital (clinical governance) | Agent instance | Authority to produce draft findings that enter the clinical workflow | Hospital deployment policy, reviewed at deployment and on change |
Cross-border? - [ ] Yes — jurisdictions involved: - [x] No (this instance is a single-jurisdiction deployment; the pattern repeats across jurisdictions, but evidence requirements and change-control triggers differ between regimes, so a policy reference cannot be assumed uniform — see Requirement 6)
Embodied (physical actuation or sensing)? - [ ] Yes — physical context: - [x] No (software decision support; the same gate pattern applies to embodied devices)
Agent action type (required; tick all that apply) - [ ] Read-only - [x] Consequential (reversible) - [ ] Irreversible
Crosses organisational boundary? (required) - [x] Yes — manufacturer ↔ hospital; evidence produced by one party must be trusted by the other at runtime. - [ ] No
Risk level (required) - [ ] Low - [ ] Medium - [x] High
4. Theme relevance
Check every theme this situation exercises, mark the single primary theme, and justify each checked theme against Section 2 above.
| Theme | Yes | Primary | Justification (required if checked) |
|---|---|---|---|
| Dynamic Identity | [ ] | [ ] | |
| Continuous Trust and Attestation | [x] | [ ] | Trustworthiness is decided at deployment and must be re-evaluated on model change, evidence change, and population drift — continuous, not one-shot. |
| Delegation | [x] | [ ] | Authority flows regulator → manufacturer → hospital → agent instance; each hop needs its evidence conditions attached. |
| Discovery and Cross-Border Trust | [ ] | [ ] | |
| Runtime Enforcement (Control Plane) | [x] | [x] | The core of the case is a per-action gate: registry state (agent/model/tool/dataset) + required evidence + minimum grade + policy reference, evaluated before the agent acts, with re-evaluation propagation on change. |
| Embodied AI Identity and Trust | [ ] | [ ] |
Related theme proposals: #42 — evidence grading for agentic AI (the V/S/M/L/P scale and authorization states); #59 — Agentic AI trust control plane WG proposal (this case is a concrete instance of its evidence workstream); field-level mapping in themes#43.
5. Requirements
One row per requirement. Type: Legal / Business / Technical. Criticality: Must / Should / Nice-to-have.
| # | Type (choose one) | Requirement description | Criticality (choose one) |
|---|---|---|---|
| 1 | Technical | A shared verdict vocabulary for runtime gates that keeps "evidence absent" and "evidence found wrong" as distinct failures with distinct remediations. | Must |
| 2 | Technical | Change semantics: any change to the model, its evidence base, or the governing policy reference triggers re-evaluation of previously accepted verdicts at every deployment point (non-monotonic: acceptances can be revoked and later restored). | Must |
| 3 | Technical | A registry model for control-plane state (agent instances, model versions, tools, datasets) that gates evaluate against. | Must |
| 4 | Technical | Silent-failure coverage: gate checks driven by a failure catalog that includes cases where headline accuracy is unchanged but the operating population has drifted. | Should |
| 5 | Business | Manufacturer change-control commitments (e.g. predetermined change control plans) must be expressible as machine-checkable policy references the hospital-side gate can consume. | Should |
| 6 | Technical | A policy reference must be scoped to the governing jurisdiction: what counts as adequate evidence, and which model changes trigger re-evaluation, differ between regulatory regimes even when the gate mechanics are identical. A gate must be able to hold and evaluate more than one such reference without assuming they are uniform. | Should |
6. Assessment criteria
Success criteria: A relying party (hospital) can configure, from publicly documented vocabulary, a gate that (a) denies execution when required evidence is absent or below grade, (b) admits it when evidence meets the required grade, and (c) automatically suspends, rolls back, and re-verifies when the model or policy reference changes — with every decision leaving an inspectable record. Measurable metric: In a reference implementation, all lifecycle receipts are reproduced deterministically (deny-before-evidence, admit-after-evidence, pause on drift, rollback, re-verify, resume), and every negative-control case (attempted execution without adequate evidence, or after an unverified change) is intercepted.
7. Duplication check
Required under ITU-T Recommendation A.7 clause 7.
Existing standards or SDOs (which existing work touches this case): National AI-enabled medical-device change-control regimes (e.g. predetermined change control plan frameworks); EU medical-device / AI legislation; IEC 62304 software lifecycle; WHO guidance on large multi-modal models for health; ISO/IEC AI management-system work. Overlap notes (why the work named above does not already solve this): These govern the manufacturer's process and the regulator's approval — they do not provide the runtime, cross-organizational piece: a shared, machine-checkable gate vocabulary (evidence grades, authorization states, re-evaluation triggers) that a relying party applies at the moment the agent acts. That runtime gap is precisely FG-TIDA's control-plane subject.
8. Maturity
Pilot status
- [x] Hypothetical
- [ ] Pilot in progress
- [ ] Deployed in production
Reference implementation: https://github.com/LGD-Eval/evaluation-protocol (evidence grader + worked examples with a one-command regression: python demo/run_worked_examples.py) and https://github.com/LGD-Eval/uibc-core (executable protocol reference: registry / evidence / gates). A hospital-scenario lifecycle demo (register → evidence-denied → gated admit → change-gate → drift → pause → rollback → re-verify → resume) is available as a runnable, dependency-free demo (one Python script plus a required JSON failure-rule catalog, standard library only) — evidence-gated medical agent demo.
Scope note: The scenario is fictional. The reference implementations demonstrate gate mechanics and deterministic lifecycle receipts only; they are not a clinical validation, a conformity assessment, or a claim of operational deployment in any hospital. The contribution is a standardization use case, not evidence of production readiness.
9. IP and confidentiality
Confidentiality level
- [x] Public
- [ ] FG-internal only
- [ ] Redact before publication
IP notes (optional): Reference implementations are Apache-2.0 / CC BY 4.0 respectively; no proprietary or confidential material is involved.
10. Assets
Link to assets: - [ ] Dataset - [x] Code - [x] Protocol - [ ] Other:
IP notes (optional):